md-19005-en - Flipbook - Side 4
on environmental and health protection can be
requested from the manufacturer.
2.8
Product processing/Installation
The membrane of the metal ceiling system is attached
to a substructure. The installation is to be carried out
by trained personnel, usually from the area of drywall
construction. The manufacturer's instructions must be
observed.
2.9
Packaging
For packaging the metal ceiling systems and
components wooden pallets, cardboard, polystyrene,
plastic sheeting, steel and plastic straps are used. The
packaging material is easily separable and can be
reused if necessary. It can be collected, sorted and
sent to the regional recycling services. Residual
material must be disposed of in accordance with the
respective national guidelines.
2.10 Condition of use
Due to the many product variants no general cleaning
and maintenance recommendation can be given.
Conditions for a long service life are based on regular
maintenance, care and repair of the product. The
material composition does not change during service
life. Documents can be requested from the respective
metal ceiling system manufacturer.
2.11 Environment and health during use
There are no known interactions between the product,
the environment and health. Volatile organic
compounds (VOC) are below the valuation limit
according to health-related Evaluation of Emissions of
Volatile Organic Compounds from Building Products
(AgBB) /AgBB evaluation scheme/.
Mechanical destruction
In the case of mechanical destruction, all of the
substances remain bound. It is to be assumed that in
the case of coated ceilings, lacquer chippings occur in
such a small amount that there are no negative
impacts on the environment.
2.14 Re-use phase
The metal ceiling systems can be removed and reused without damaging the product.
2.15 Disposal
In accordance with the Waste Classification Ordinance
(AVV) and the European Waste List (EWL), the waste
code is:
17 04 05 – Iron and steel.
17 04 02 – Aluminium.
2.16
Further information
DAMPA ApS: www.dampa.com
durlum GmbH: www.durlum.de
FURAL Systeme in Metall GmbH:
www.fural.com
Geipel® Genex-Vertrieb Ltd. & Co. KG:
www.geipel-genex.de
Georg Haag AG: www.georghaag.com
Hunter Douglas Europe B.V.:
www.hunterdouglasarchitectural.eu
König GmbH & Co. KG:
www.koenigprodukte.de
Lindner AG: www.Lindner-Group.com
Metalit Metallbauelement AG: www.metalit.ch
Nagelstutz und Eichler GmbH & Co. KG:
www.ne-metalldecken.de
2.12 Reference service life
Based on the useful lives of building components
according to the Sustainable Building Assessment
System /BBSR-Table 2017/, Service Lives of
components for life cycle assessment according to
Assessment System for Sustainable Building (BNB),
the reference service life of metal ceilings exceeds 50
years.
2.13
Extraordinary effects
Fire
The metal ceiling systems made of aluminium declared
here correspond to the class A of building products
regarding their fire performance, according to /EN
13501-1/. The class of flaming droplets is d0 and the
class for smoke density is pre-defined as s1.
Fire protection
Name
Building material class
Smoke gas development
Burning droplets
Value
A2
s1
d0
Water
There are no known effects on the environment in the
event of unforeseen ingress of water.
4
Environmental Product Declaration TAIM e.V. - Verband Industrieller Metalldeckenhersteller – Metal ceiling systems
made of aluminium