3.0
3.1
INTERNAL AREAS
ENTRY FOYER
USE OF SPACE
CAPACITY
The Internal Arrival Point for the Building
Nominal 50 People Standing
DESCRIPTION OF SPACE
A space dedicated to the arrival of pedestrians to the inside of the building.
To provide a fully enclosed area to gather on arrival.
The space is to be a memorable location for visitors and locals which connects people with place.
Include open clear wall space with a hanging rail for hanging artwork and similar.
CONNECTED SPACES
Directly Connected to:
Covered Forecourt | Community Hall
Indirectly Connected to:
Female Toilet | Male Toilet | Universal Access Toilet
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
63 m2
7,000 mm
9,000 mm
3,000 mm
REFERENCE DOCUMENTS THAT APPLY
Camden Council
Consultation with Camden Council to establish specific requirements.
MATERIALS
LOCATION
Material
Finish
Floor
Concrete
R10
Slab with
Colour
Dimension
NOTE
White Colours are not
150mm
White Colours are not
High
suitable
suitable
Floor Vinyl
Skirting
Cove Floor
Match Floor
Finish to
Finish
Wall
Wall
9 mm Fibre
Cement
Paint
Not Required if
Plasterboard is used
Sheet
PAGE 90
APPENDIX A - COMMUNIT Y CENTRE