23 428196 Camden Public Building Design Manual 1 August 2023 - Flipbook - Page 71
1.0
1.3
EXTERNAL AREAS UNCOVERED
UNCOVERED FORE COURT
USE OF SPACE
CAPACITY
The Arrival Point for the Building
Nominal 50 People Standing
DESCRIPTION OF SPACE
A space dedicated to the arrival of pedestrians to the building.
To provide an uncovered area to gather on arrival.
The space may incorporate a place to stage impromptu or planned performances or an outdoor
cinema with a film played on the wall of the building.
The space is to be a memorable location for visitors and locals with connection to people and place.
The space should be able to be trafficked by vehicles.
CONNECTED SPACES
Directly Connected to:
Covered Forecourt | Pedestrian Access Paths | Landscaped Area
Indirectly Connected to:
Car Park
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
75 m2
5,000 mm
15,000 mm
Not Applicable
REFERENCE DOCUMENTS THAT APPLY
Camden Council
Open Space Design Manual
MATERIALS
LOCATION
Floor
Material
Finish
Segmental
R10
Pavement
Colour
Dimension
NOTE
White Cement Base and
Exposed Aggregate are
not suitable
Fall to Landscaped Area
CAMDEN PUBLIC BUILDING DESIGN MANUAL
PAGE 71