2.2
CONCRETE SURROUND
USE OF SPACE
CAPACITY
The Area for Pedestrian Traffic Around the Building
Specific to Building
DESCRIPTION OF SPACE
To protect the full external perimeter at the base of the external face of the Building.
Construct a cold tooled joint between the concrete surround and the external face of the building
construction. Fall the concrete away from building. Ensure a solid compacted base and continuous
concrete edge thickening to the outside edge of the concrete surround.
A covered external space that has a concrete surface finish or segmental pavement surface finish
with a minimum width of 1,200 mm does not require a concrete surround.
CONNECTED SPACES
Directly Connected to:
Event Space | Landscaped Area
Indirectly Connected to:
Other Hard Stands
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
Specific to Building
Specific to Building
1,200 mm
3,000 mm
REFERENCE DOCUMENTS THAT APPLY
Camden Council
Open Space Design Manual
MATERIALS
LOCATION
Floor
Material
Finish
Colour
Dimension
NOTE
Concrete Slab
R10 with
Portand
Minimum
White Cement
Sealant
Cement
100mm
Base and Exposed
or
Thick
Aggregate are not
Coloured
suitable
Pigment
Low Level Wall
Face
Glazed
Brickwork
Solid Colour through
full extent of brick
to Match its Surface
Colour
CAMDEN PUBLIC BUILDING DESIGN MANUAL