23 428196 Camden Public Building Design Manual 1 August 2023 - Flipbook - Page 307
1.2
WATE R TAN K
USE OF SPACE
CAPACITY
The Storage Area for a Water Tank
Specific to the Building
DESCRIPTION OF SPACE
A space dedicated to the collection of rain or stormwater that will be re-used on the site.
To provide for the storage of water collection tanks.
Water tank or tanks are to be fully sealed, secured and provide for access by Camden Council only
in order to maintain the tank in conjunction with associated connections.
To be suitably located for gravity fed water collection and distribution.
CONNECTED SPACES
Directly Connected to:
Event Space
Indirectly Connected to:
Open Space Landscaped Areas
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
Specific to the
Roof Area
Specific to the
Roof Area
Specific to the
Roof Area
Not Required | Specific to Tank
REFERENCE DOCUMENTS THAT APPLY
Camden Council
Open Space Design Manual
Tank Manufacturers Current Written Requirements
MATERIALS
LOCATION
Floor
Material
Finish
Colour
Dimension
NOTE
Concrete Slab
Smooth
Trowel with
Sealant
Penetrating
Sealant
Portand
Minimum
100mm
Thick
White Cement
Compacted
Galvanised
Base
Cement
or
Coloured
is not suitable
Fall to Landscaped
Pigment
Base in Concrete
Area
Confirm
Requirements with
Tank Manufacturer