3.7
FEMALE TOILET
USE OF SPACE
CAPACITY
The Area for Female Members of the Public to Use the Toilet
Specific to the Building
DESCRIPTION OF SPACE
A space dedicated for the use of female members of the community, including young
children, to use the toilet.
To provide a fully enclosed area for provision of toilet facilities.
Ensure to increase the number of toilets to this space if the building is servicing the needs
of predominantly female sports whose players may be using the facility. This is particularly
applicable to Netball Courts.
Ensure that there is not a line of sight from outside the entry to the Toilet Area to the Internal Layout
of the Toilet Area by incorporating a wall switchback or similar.
CONNECTED SPACES
Directly Connected to:
Spectator Seating | Kiosk | Canteen Queuing Area
Indirectly Connected to:
Sports Field
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
24 m2
4,000 mm
6,000 mm
2,600 mm
REFERENCE DOCUMENTS THAT APPLY
Australian Standards
AS1428 Design for Access and Mobility
Camden Council
Consultation with Camden Council to establish specific requirements.
MATERIALS
LOCATION
Floor
Material
Finish
Concrete Slab
R10
with Floor Tile
Colour
Dimension
NOTE
White Colours are
not suitable
Fall to Floor Waste
Skirting
Cove Floor
Match Floor
Finish to Wall
Finish
CAMDEN PUBLIC BUILDING DESIGN MANUAL
Nominal 150
White Colours are
mm High
not suitable
PAGE 205