23 428196 Camden Public Building Design Manual 1 August 2023 - Flipbook - Page 175
2.4
KIOSK | CANTEEN QUEUING AREA
USE OF SPACE
CAPACITY
The Area for Patrons to Queue for the Kiosk | Canteen
Specific to the Building
DESCRIPTION OF SPACE
A space dedicated for patrons to queue for service at the Kiosk | Canteen Servery.
To provide a covered area to gather and shelter from weather to wait for service.
The space is to be simple, safe and practical for use by spectators of all ages.
CONNECTED SPACES
Directly Connected to:
Spectator Seating | Kiosk | Canteen
Indirectly Connected to:
Toilets | First Aid
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
18 m2
6,000 mm
3,000 mm Depth
from the Kiosk |
Canteen Servery
3,000 mm
REFERENCE DOCUMENTS THAT APPLY
Camden Council
Consultation with Camden Council.
MATERIALS
LOCATION
Floor
Material
Finish
Colour
Dimension
NOTE
Concrete Slab
R10 with
Portand
Minimum
White Cement
Sealant
Cement
100mm
Base and Exposed
or
Thick
Aggregate are not
Coloured
suitable
Pigment
Ceiling | Soffit
9mm Fibre
Paint
Cement Sheet
Expressed Joint in
Sheet Lining is not
suitable
Cornice
Square Edge
CAMDEN PUBLIC BUILDING DESIGN MANUAL
Paint
Shadowline is not
suitable
PAGE 175