REFERENCE DOCUMENTS THAT APPLY
Camden Council
Waste Management Guidelines with specific reference to Commercial
Development | Commercial Premises | Community Facility requirements
For storage of all required bin receptacles refer to Clause 4.4 Multi-Dwelling
Housing as well as Clause 4.6 Mixed Use Developments
Sydney Water Trade Waste requirements.
AS4674 Design, Construction and Fit-Out of Food Premises Where
construction requirements for waste storage areas [enclosed spaces and
open] relate to food premises.
MATERIALS
LOCATION
Floor
Material
Finish
Colour
Dimension
NOTE
Concrete Slab
Smooth
Portand
Minimum
White Cement
Trowel
Cement
100mm
Base and Exposed
Finish with
or
Thick
Aggregate are not
Sealant
Coloured
suitable
Pigment
Screen Wall
Steel Frame
Galvanised
with Steel
Plate Panel or
Minimum
Screen panels
1,800 mm
should be decorative
High
and provide an
Bar Inserts
opportunity to
incorporate artwork
in the design
Low and High
Level Walls are not
required if a Screen
Wall is used
Low Level Wall
Face
Glazed
Brickwork
Solid Colour through
full extent of brick
to match its surface
colour
Low Level Walls
are not required if a
Screen Wall is used
High Level Wall
Perforated
Powdercoat
Metal Panel
or Clear
Anodised
White colours are
not suitable
High Level Walls
are not required if a
Screen Wall is used
Ceiling | Soffit
9mm Fibre
Cement Sheet
Paint
Expressed Joint in
Sheet Lining is not
suitable
CAMDEN PUBLIC BUILDING DESIGN MANUAL
PAGE 161