3.18 C L E A N E R S S T O R E
USE OF SPACE
CAPACITY
The Area for Cleaners Storage
One Person Standing
DESCRIPTION OF SPACE
A space dedicated for use by Camden Council to store cleaning items for the building.
To provide a fully enclosed area for storing cleaning equipment and products.
Connecting the Cleaners Store directly to the Female Toilet, Male Toilet, Universal Access Toilet,
Shared Wash Area, Entry Foyer, Kitchen or any other store is not suitable.
CONNECTED SPACES
Directly Connected to:
To Suit Building
Indirectly Connected to:
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
3 m2
1,000 mm
3,000 mm
2,600 mm
REFERENCE DOCUMENTS THAT APPLY
Camden Council
Consultation with Camden Council to establish specific requirements.
MATERIALS
LOCATION
Floor
Material
Finish
Concrete Slab
R10
with Floor Tile
Colour
Dimension
NOTE
White Colours are
not suitable
Fall to Floor Waste
Skirting
Wall
Cove Floor
Match Floor
Finish to Wall
Finish
9 mm Fibre
Gloss
Cement Sheet
with Wall Tile
150mm
White Colours are
High
not suitable
Wall Tile Full Height
of Wall and to its
Full Extent
Epoxy Grout Not
Required