23 428196 Camden Public Building Design Manual 1 August 2023 - Flipbook - Page 121
3.8
SHARED WASH AREA
USE OF SPACE
CAPACITY
The Area for Use by All to Wash Hands
Specific to Building
DESCRIPTION OF SPACE
A space dedicated for use by anyone including young children.
To provide a partially enclosed area for provision of hand washing facilities for all ages including
young children and particularly for those using the Female Toilet and Male Toilet.
This space may be internal and not connected directly to the outside by a window.
The hand washing facilities in this space are not required to comply with AS1428.
CONNECTED SPACES
Directly Connected to:
Female Toilet | Male Toilet
Indirectly Connected to:
Community Hall | Court Yard
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
10 m2
2,000 mm
5,000 mm
2,600 mm
REFERENCE DOCUMENTS THAT APPLY
Camden Council
Consultation with Camden Council to establish specific requirements.
MATERIALS
LOCATION
Material
Finish
Floor
Concrete
R10
Slab with
Colour
Dimension
Floor Tile
Skirting
NOTE
White Colours are not
suitable
Fall to Floor Waste
Cove Floor
Match Floor
Finish to
Finish
150mm
White Colours are not
High
suitable
Wall
Wall
9 mm Fibre
Gloss
Cement
Sheet with
Wall Tile
Wall Tile Full Height
of Wall and to its Full
Extent
Epoxy Grout Not
Required
CAMDEN PUBLIC BUILDING DESIGN MANUAL
PAGE 121