23 428196 Camden Public Building Design Manual 1 August 2023 - Flipbook - Page 116
3.7
UNIVERSAL ACCESS TOILET
USE OF SPACE
CAPACITY
The Area for Use by All as Toilet and Change Facilities
One Minimum
DESCRIPTION OF SPACE
A space dedicated for use by anyone including young children.
To provide a fully enclosed area for provision of universally accessible toilet facilities in accordance
with AS1428 as well as change facilities for all ages including young children.
CONNECTED SPACES
Directly Connected to:
Shared Wash Space | Community Hall
Indirectly Connected to:
Court Yard
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
6 m2
2,000 mm
3,000 mm
2,600 mm
REFERENCE DOCUMENTS THAT APPLY
Camden Council
AS1428 Design for Access and Mobility
MATERIALS
LOCATION
Material
Finish
Floor
Concrete
R10
Slab with
Colour
Dimension
Floor Tile
Skirting
NOTE
White Colours are not
suitable
Fall to Floor Waste
Cove Floor
Match Floor
Finish to
Finish
150mm
White Colours are not
High
suitable
Wall
Wall
9 mm Fibre
Cement
Sheet with
Wall Tile
Gloss
Wall Tile Full Height
of Wall and to its Full
Extent
Epoxy Grout Not
Required