3.6
MALE TOILET
USE OF SPACE
CAPACITY
The Area for Male Community Members to Use the Toilet
Specific to the Building
DESCRIPTION OF SPACE
A space dedicated for the use of male members of the community, including young children,
to use the toilet.
To provide a fully enclosed area for provision of toilet facilities.
Ensure that there is not a line of sight from outside the entry to the Toilet Area to the Internal Layout
of the Toilet Area by incorporating a wall switchback or similar.
CONNECTED SPACES
Directly Connected to:
Shared Wash Area | Community Hall
Indirectly Connected to:
Court Yard
DIMENSIONS OF SPACE
Nominal Area
Nominal Length
Nominal Width
Min Ceiling | Soffit Height
24 m2
4,000 mm
6,000 mm
2,600 mm
REFERENCE DOCUMENTS THAT APPLY
Australian Standards
AS1428 Design for Access and Mobility
Camden Council
Consultation with Camden Council to establish specific requirements.
MATERIALS
LOCATION
Material
Finish
Floor
Concrete
R10
Slab with
Colour
Dimension
Floor Tile
Skirting
NOTE
White Colours are not
suitable
Fall to Floor Waste
Cove Floor
Match Floor
Finish to
Finish
150mm
White Colours are not
High
suitable
Wall