23 426870 Camden Standard Landscape Details - August 2023 - Flipbook - Page 94
CENTRED 600mm MINIMUM
(1000mm PREFERRED)
CONCRETE FOOTPATH
WIDTH VARIES (MIN 1200 mm )
CENTRED 600mm
MINIMUM(1000mm
PREFERRED)
TURF
300
HARDWOOD STAKES AS NOTED AND 50mm
HESSIAN BAND STAPLED TO STAKE
1500mm OR AS SPECIFIED
PLANTING HOLE - REFER NOTES
75mm DEPTH OF MULCH AS SPECIFIED
TO BASE OF TREE, FINISH JUST BELOW
FOOTPATH & KERB LEVEL
600mm ROOT BARRIER TO EDGE OF TREE PIT
KERB DRAIN INTO PLANTING HOLE
CONCRETE EDGE AS REQUIRED
TEMPORARY TREE GUARD - REFER NOTES
KERB
GUTTER
ROAD
300
600mm ROOT BARRIER TO BACK
OF KERB/FOOTPATH. INSTALLED
ADJACENT TO THE PATH AS PER
MANUFACTURER'S STANDARD
SO
INDICATIVE LOCATION OF
SHARED SERVICES TRENCH
TURF
CONTAINER ROOTBALL
PLANTING HOLE - REFER NOTES
SUB
CULTIVATED SUBGRADE
300mm DEPTH
150mm WIDE CONCRETE EDGE TO FINISH FLUSH
WITH TOP OF KERB AND ADJACENT PATH.
TS
9.1
TREE PLANTING IN PARKING BAY WITH PASSIVE IRRIGATION KERB DRAIN
PLAN - TYPICAL
1:20 @ A1
TS
9.2
TREE PLANTING IN PARKING B
KERB DRAIN
SECTIO
CENTRED 600mm MINIMUM
(1000mm PREFERRED)
CONTAINERISED STREET TREE AS SPECIFIED
1500mm OR AS SPEC
C
HARDWOOD STAKES AS NOTED AND 50mm
HESSIAN BAND STAPLED TO STAKE
GRADE MULCH SO THAT IT IS KEPT
AT LEAST 50mm CLEAR OF THE STEM
COLLAR. INSTALL EXPANDABLE
PLASTIC COLLAR GUARD
75mm DEPTH OF MULCH AS SPECIFIED TO
BASE OF TREE, FINISH JUST BELOW
FOOTPATH & KERB LEVEL
FORM SMALL BERMED DISH CLOSE TO
THE EDGE OF POTTED ROOTBALLL TO
FACILITATE ENTABLEMENT WATERING
HARDWOOD STAKES AS
DESCRIBED ABOVE AND
50mm HESSIAN BAND
STAPLED TO STAKE
ENSURE POTTED SOIL LEVEL AND
STEM COLLAR IS SET MAX 200mm
FROM TOP OF KERB LEVEL
CONCRETE EDGE AS REQUIRED
KERB DRAIN INTO PLANTING HOLE
ROAD
KERB
600mm ROOT BARRIER TO BACK
OF KERB/FOOTPATH. INSTALLED
ADJACENT TO THE PATH AS PER
MANUFACTURER'S STANDARD
150
FILTER MEDIA
600mm ROOT BARRIER TO BACK OF
KERB/FOOTPATH. INSTALLED INSTALLED
BELOW THE INVERT OF THE KERB AS PER
MANUFACTURER'S STANDARD
TRANSITION LAYER
INDICATIVE LOCATION OF
SHARED SERVICES TRENCH
100
KERB
DRAINAGE LAYER
PLANTING HOLE - REFER NOTES
SUBGRADE
INDICATIVE LOCATION OF
STORMWATER SERVICES
SUBGRADE
100mm DIAMETER SLOTTED PVC PIPE
CONNECTED TO STORMWATER SYSTEM
TS
9.3
TREE PLANTING IN PARKING BAY WITH PASSIVE IRRIGATION KERB DRAIN _ OPTION
SECTION - TYPICAL
1:20 @ A1
REVISION DATE
DESCRIPTION
DRAWN
VERIFIED
APPROVED
A
DRAFT FOR REVIEW
NB
TV
XX
27/10/2022
APPROVALS
TS
9.4
TREE PLANTING IN PARKING B
KERB DRAIN
ELEVATION
PROJECT
CAMDEN STANDARD DETAILS
TEAM LEADER
RECOMMENDED DATE: 27/10/2022
CAMDEN LGA
SHEET TITLE
STREET TREE PLANTING - PARKING BAY