23 426870 Camden Standard Landscape Details - August 2023 - Flipbook - Page 63
10 100
PARK INFORMATION MARKER
PARK INFORMATION MARKER TO BE 8 mm STAINLESS
STEEL. MARINE GRADE 316 WITH SMOOTH EDGES. FACE
SURFACE NON DIRECTIONAL LINISH FINISH. FIXING IS BE
STAINLESS STEEL SLEEVE AND PIN FIXING OR SIMILAR
FIXINGS ARE NOT VISIBLE ON THE FACE. GRAFFITI
REPELLENT OR METHOD OF GRAFFITI REMOVAL TO BE
INCLUDED. METHOD OF FIXING AND GRAFFITI
REPELLENT TO BE DOCUMENTED IN SHOP DRAWING
SAWN CUT SANDSTONE BLOCK
1750
1800
1750
10
10
NOTE:
1. SHOP DRAWINGS ARE TO BE PROVIDED TO THE
SUPERINTENDENT FOR APPROVAL.
2. SIGNAGE IS REQUIRED TO HAVE APPROVAL FROM A
STRUCTURAL ENGINEER.
3. REFER SPECIFICATION NOTES FOR FURTHER
INFORMATION.
1800
10
10
50
100
110
400
2 x 12Ø x 300 LONG SS DOWELS PER BLOCK,
EPOXIED INTO 14Ø HOLE IN SANDSTONE
400
110
100
50
50
ADJACENT SURFACE
CONCRETE FOOTING 25 MPa
COMPACTED SUBGRADE
50
EXISTING SUBGRADE
EXISTING SUBGRADE
350
- FRONT VIEW
SI
PARK INFORMATION MARKER - SIDE VIEW
1:20 @ A1
3.3
PLAN - TYPICAL
1:20 @ A1
NOTE:
1. SHOP DRAWINGS ARE TO BE PROVIDED TO THE
SUPERINTENDENT FOR APPROVAL.
2. SIGNAGE IS REQUIRED TO HAVE APPROVAL FROM A
STRUCTURAL ENGINEER.
3. REFER SPECIFICATION NOTES FOR FURTHER
INFORMATION.
400
2000
2000x400mm NAMING SIGN TO BE
PRINTED ON STEEL AND BOLTED TO
POSTS FROM BEHIND
1000
EDGES OF SIGN TO BE MANUALLY
DEBURRED IN ORDER TO REMOVE ALL
SHARPE EDGES. ALL CORNERS TO HAVE
A 10mm RADIUS
MILD STEEL (GRADE 350) ROUND POST
POWDER COATED WITH INTERPON TEXTURE
SABLE BASS OR APPROVED EQUIVALENT
100
REFER GENERAL ARRANGEMENTS PLAN
FOR ADJACENT FINISHES
400
MILD STEEL (GRADE 350) ROUND POST IN
CONCRETE FOOTING (MIN 300mm IN DEPTH)
CONCRETE FOOTING 25 MPa
COMPACTED SUBGRADE
EXISTING SUBGRADE
400
SI
PARK NAMING SIGN
2.2
SECTION - TYPICAL
1:20 @ A1
DRAFT
NOTES
1.
2.
3.
4.
SCALE
SHOWN AS PER DETAILS @ A1
DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.
ALL SERVICES ARE SHOWN AT APPROXIMATE LOCATION ONLY. ALL SERVICES TO BE CHECKED FOR
LOCATION AND DEPTH PRIOR TO COMMENCEMENT OF WORKS. LOCATION OF PRIVATE SERVICE
FACILITIES IS NOT SHOWN. LOCATE AND ADJUST TO SUIT NEW WORKS.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, SPECIFICATIONS,
REPORTS AND DRAWINGS. IF THERE IS ANY CONFLICTING INFORMATION WITHIN ALL RELEVANT
CONTRACTS, SPECIFICATIONS, REPORTS AND DRAWINGS SEEK IMMEDIATE CLARIFICATION FROM
SUPERINTENDENT BEFORE PROCEEDING.
CONFIRM ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO COMMENCEMENT OF WORK
THESE DESIGNS PLANS AND SPECIFICATIONS AND THE COPYRIGHT THEREIN ARE THE PROPERTY OF
CAMDEN COUNCIL AND MUST NOT BE USED, REPRODUCED OR COPIED, WHOLLY OR IN PART OR
TRANSMITTED IN ANY FORM OR BY ANY MEANS WITHOUT THE EXPRESS WRITTEN PERMISSION OF
CAMDEN COUNCIL.
SHEET No.
FU - SI - S1
STATUS
DRAFT
REVISION
A