23 426870 Camden Standard Landscape Details - August 2023 - Flipbook - Page 48
SYNTHETIC SOFT FALL
ATTENUATION LAYER
MINIMUM 15mm COLOURED
RUBBER FINISHED SURFACE
75 MIN.
CROSSF
MINIMUM 75mm DEEP DGB20 TO 99%
STANDARD DRY COMPACTION
VARIES
75
CROSSFALL 1%-2.5%
VARIES
MINIMUM 75mm DEEP DGB20 TO 99%
STANDARD DRY COMPACTION
15
RUBBER CUSHION LAYER. DEPTH VARIES
VARIES
SYNTHETIC SOFTFALL WEAR LAYER
FINISH FLUSH WITH ORGANIC MULCH
SOFTFALL SURFACE
COMPACTED SUB GRADE 1% MIN. FALL
TO DRAINAGE
EXISTING SUBGRADE
WR WET POUR RUBBER - IMPACT ATTENUATION
WR WET POUR RUBBER SOFTFALL
1.1
1.2
SECTION - TYPICAL
1:10 @ A1
SECTION - TYPICAL
NOTE: SYNTHETIC SOFT FALL EDGING MATERIAL MAY VARY.
BRICK, SANDSTONE, OR OTHER HARD EDGE MAY BE USED AS
AGREED WITH CAMDEN COUNCIL.
KEY JOINT METHOD
50-100mm
MIN. 15mm THICK SURFACE WEAR LAYER
150
SYNTHETIC SOFT FALL ATTENUATION
LAYER AS REQUIRED
32MPa STRENGTH GRADE CONCRETE,
10mm BEVEL ON EXPOSED EDGES
ADJACENT TURF
MINIMUM 75mm DEEP DGB20 TO 99%
STANDARD DRY COMPACTION
COMPACTED SUB GRADE 1% MIN. FALL
TO DRAINAGE
100mm DIA. SLOTTED DRAINAGE
LINE IN FILTER SOCK CONNECTED
TO STORM WATER
WR WET POUR RUBBER SOFTFALL TO TURF
1.4
SECTION - TYPICAL
1:10 @ A1
REVISION DATE
DESCRIPTION
DRAWN
VERIFIED
APPROVED
A
DRAFT FOR REVIEW
NB
TV
XX
27/10/2022
APPROVALS
PROJECT
CAMDEN STANDARD DETAILS
TEAM LEADER
RECOMMENDED DATE: 27/10/2022
CAMDEN LGA
SHEET TITLE
ARTIFICIAL SURFACE - WET POUR RUBB