32MPa CONCRETE SLAB TURNED DOWNTO MEET EXISTING SUB GRADE2x N12 BARS SPACED EVENLY TO EACH FACE.LAP BARS MIN 420mm AT SPLICESSUB BASE FALLS TO LOW POINTFILTER FABRIC TO SEPARATE SOFT FALLMATERIAL FROM SUB BASEFALL TO LOW POINTFALL TO LOW POINTVARIES - 700 MAX.SOFTFALLDEPTH VARIESVARIES - 700 MAX.SOFTFALL PLAY AREA 300mm - 500mm DEPTHDRAINAGE TRENCH TO LOW POINT OF GRADED SUBBASE. FILL WITH DRAINAGE MATERIAL100mm DIA. SLOTTED DRAINAGE LINE IN FILTER SOCKCONNECTED TO STORM WATERCOMPACTED SUB BASEEXISTING SUB GRADE150 MIN.200150 MIN.300E TO TURFPE CONCRETE TURN DOWN EDGE TO MULCH SOFTFALL2.31:10 @ A1RETESECTION - TYPICAL1:10 @ A1DRAFTNOTES1.2.3.4.SCALESHOWN AS PER DETAILS @ A1DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.ALL SERVICES ARE SHOWN AT APPROXIMATE LOCATION ONLY. ALL SERVICES TO BE CHECKED FORLOCATION AND DEPTH PRIOR TO COMMENCEMENT OF WORKS. LOCATION OF PRIVATE SERVICEFACILITIES IS NOT SHOWN. LOCATE AND ADJUST TO SUIT NEW WORKS.THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT CONTRACTS, SPECIFICATIONS,REPORTS AND DRAWINGS. IF THERE IS ANY CONFLICTING INFORMATION WITHIN ALL RELEVANTCONTRACTS, SPECIFICATIONS, REPORTS AND DRAWINGS SEEK IMMEDIATE CLARIFICATION FROMSUPERINTENDENT BEFORE PROCEEDING.CONFIRM ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO COMMENCEMENT OF WORKTHESE DESIGNS PLANS AND SPECIFICATIONS AND THE COPYRIGHT THEREIN ARE THE PROPERTY OFCAMDEN COUNCIL AND MUST NOT BE USED, REPRODUCED OR COPIED, WHOLLY OR IN PART ORTRANSMITTED IN ANY FORM OR BY ANY MEANS WITHOUT THE EXPRESS WRITTEN PERMISSION OFCAMDEN COUNCIL.SHEET No.HS - PE - S2STATUSDRAFTREVISIONA