23 426870 Camden Standard Landscape Details - August 2023 - Flipbook - Page 36
CONCRETE PATH
32MPa CONCRETE SLAB TURNED DOWN
TO ACCOMMODATE CHANGE IN LEVELS
32MPa CONCRETE SLAB TURNED DOWN
TO MEET EXISTING SUB GRADE
GARDEN BED SHOWN. ADJACENT
SURFACE MAY VARY. REFER FINISHES
DRAWINGS
VARIES - 700 MAX.
150 - 500 MAX.
REGRADED AREA WITH TURF FINISHED
FLUSH TO CONCRETE
2x N12 BARS SPACED EVENLY TO EACH
FACE. LAP BARS MIN 420mm AT SPLICES
COMPACTED CLEAN FILL TO ACHIEVE REQUIRED
LEVELS IN AREA TO BE REGRADED
2x N12 BARS SPACED EVENLY TO EACH
FACE. LAP BARS MIN 420mm AT SPLICES
EXISTING GROUND LINE AFTER CUT
EXISTING SUBGRADE
SUB-GRADE UNDER PAVEMENT
COMPACTED TO 98% CBR4
COMPACTED SUB BASE
EXISTING SUBGRADE
UNDER GARDEN BED
150 MIN.
PE
CONCRETE TURN DOWN EDGE TO GARDEN BED
PE CONCRETE TURN DOWN EDGE
2.1
SECTION - TYPICAL
2.2
1:10 @ A1
REVISION DATE
DESCRIPTION
DRAWN
VERIFIED
APPROVED
A
DRAFT FOR REVIEW
NB
TV
XX
27/10/2022
APPROVALS
SECTION - TYPICAL
PROJECT
CAMDEN STANDARD DETAILS
TEAM LEADER
RECOMMENDED DATE: 27/10/2022
CAMDEN LGA
SHEET TITLE
PAVEMENT EDGE - TURN DOWN CONCR