XT025 - Black case expansion dial thermometers with capillary
Product features:
Temperature
" Thermometer with stainless steel bezel and capillary stem
" High quality liquid expansion measuring system
" 150mm dials with back nange for surface mounting and
100mm dials with choice of back nange or front nange for
panel mounting.
" Plastic coated bronze or full copper capillary (dependant
on temperature range)
" Supplied complete with brass pocket
" Choice of temperature ranges and stem lengths
" Brannan quality and accuracy
" Personalised instrumentation available on request
" For dry indoor installations
" Wide range of associated accessories available
Product speciocations:
Measurement for life.
Dial diameters
Design
Accuracy class
Ranges
Case
Bezel
Connection
Stem lengths
Pockets
Capillary
44
Sensor mechanism
Window
Pointer
Filling
Operating temperature
Storage temperature
Protection
Calibration
Ø100mm & 150mm
BS EN 13190
2
-20 to +60°C&F through to 0 to +250°C&F
Black steel
304 stainless steel
1/2= BSP bottom connection with back nange or back connection with front nange
75mm, 150mm & 200mm
50mm, 100mm & 150mm Brass (SS 304 or SS316 available on request)
1.5m, 3m & 5m
Ranges
+200°C: full copper capillary
Liquid expansion (kerosene olling)
PMMA
Black plastic
Dry
0 to +40°C (higher or lower ambient temperatures can cause indication errors)
-40 to +60°C
IP 54 (BS EN 60529:1992)
Certiocate traceable to recognised national standard or statement of conformity,
if required
Product accessories:
Please see accessories section of this catalogue for associated
items for use with these thermometers.
" Pockets
" Self sealing test plugs
brannan.co.uk