Aagaard Web Katalog - Catalog - Page 21
FILTER
.
Chain filter AKF
Area m²/module:
Filterbags/module:
Filterbag media:
Dust emission:*
Rotary valve
ATEX**
Weight kg/module:
Elektrical
Chain drive
Movement sensor
Cleaning fan
Door switch
Ex-sensor
DAK
DAK XL
53,5 m²
81,5 m²
32 pce.
50 pce
PP Alu-coated standard – PE needlefelt as an option.
< 0,2 mg/m3
Outlet for ABS 1000
Zone 20/21/22 on dust-side.
Kmax=200 bar m/s
App. 600 kg
1,1kW – 230/400Vac
24Vdc PNP inductive sensor
1,5 kW / filtermodule – 230/400Vac
(1xNC+1xNO) at each end of the filter.
1 x NC+1XNO per module
* Depending on dust type and composition. It is recommended to use police-filter/return air filter in countries
where return air directly to workfloor is allowed. The used of a heat exchanger is a good alternative.
HIGH-END DUST HANDLING SOLUTION
FILTEERS – FANS – DUCTING – SILOS – OUTFEEDERS – CONVEYERS – TRUCKLOADERS - CYCLONES
Aagaard A/S
Smedevænget 14
DK-9560 Hadsund
+45 96 53 12 00
mail@aagaard-systems.dk
www.aagaard-systems.dk
Datablad nr.: 0404R17
** Explosion calculation acc. to EN 14491 can be done on specific dust-types.