DAMPA Clip In Tile e-katalog - Catalog - Page 6
DAMPA® Clip-In tiles
The installation of DAMPA® Clip-In, with or without bevelled edge,
in a concealed suspension system creates a flat and uniform ceiling surface.
Primary Grid/Carrier
and Hanger Distances
C
D
A
B
All carrier and hanger centres
are maximum distances
A
Wall first Carrier No. 14
600 mm
B
Carrier No.14 to next Carrier No.14
1200 mm
C
Wall to first hanger
600 mm
D
Hanger to hanger
1200 mm
Installation Principles
Installation of Tiles
Packaging
Unless the carriers can be installed directly to
existing gridwork, we recommend a secondary
grid system to minimise the number of suspension points and provide for greater flexibility
during installation.
Perimeter tiles are installed first by engaging the
cut edge into the edge trim and then securing
the profiled edge into the carrier.
Tiles and painted perimeter trims are supplied
in rigid, non returnable cardboard boxes.
DAMPA’s primary grid system consists of
Carrier No. 14 and the well-proven rigid and
easily adjustable suspension principle.
Carrier No. 4 is connected to the primary grid
by use of Coupling Clip No. 3, whereas Carrier
No. 10 is to be secured to the primary grid by
use of pop rivets.
Perimeter Details
For ceiling layouts ending with full tiles, use
Carrier No. 10 parallel to the other carrier along
the perimeter where appropriate.
Where tiles have to be cut, use Edge Trim
No. 11 for aluminium and Edge Trim No. 36
for steel tiles. If so required, tiles with bevelled
edge can by use of Carrier No. 10 be installed
with an open groove of variable size surrounding each individual tile.
6
Corner tiles must be installed before adjacent
perimeter tiles.
Tiles with bevelled edge and with square edge
are secured to Carrier No. 4 (or No. 10) by
applying an upward pressure using the palm
of the hand at all four corners.
Clip-In Carriers
The distance from wall to first Carrier No. 4 or
to Carrier No. 10 depends on the ceiling layout,
just as the distances between clip-in carriers
depend on the modular size of the different tiles
available.
If lighting, air diffusers or other integrated
fittings are incorporated into the ceiling, it may
be necessary to provide additional hangers to
accommodate the extra weight.
Galvanised suspension components are supplied in standard bundles. All materials has to
be stored under cover in a dry, ventilated area.
Classification
Approved as C-class material by leading
classification societies.
This includes both perforated and unperforated
executions, with or without acoustic felt and/or
inlay of mineral wool, whether sealed in
PE-sleeves or not.
Functionality and Quality
All DAMPA® Marine Ceiling Systems are
manufactured to high standards within close
tolerances to ensure accurate, fast and
reliable installation.
The DAMPA® Marine Ceiling Systems
are produced in accordance with
DS/EN ISO 9001