DAMPA 10 100 200 300 modules - Catalog - Page 3
Installation of DAMPA® 10/100/200/300
Modular Carrier No. 40 supports all types of ceiling units.
The carriers are suspended by adjustment clips and perforated hangers.
After fixing of the perimeter trims, the modular
carriers are suspended.
When using either edge trims or angle runners,
a slot is cut at the ends of the modular carriers
to splice into the upper flange of the edge trim
or the horizontal flange of the angle runner.
The first and last ceiling units should ideally be
greater than half their module width.
When using angle runners or open edge details,
a leading edge return unit should be ordered as
the first ceiling or it can be formed on site.
Max. distance
1
2
Edge
Trim Type 1 is used at right angles
to the ceiling units and Edge Trim Type 2
parallel to support cut units.
Edge trims are fastened to the wall at
intervals of maximum 500 mm.
Aluminium
Steel
A (open edge detail)
100 mm
100 mm
A (edge trim)
300 mm
B
1600 mm*
1350 mm
C
300 mm
300 mm
D
1600 mm**
1350 mm
3
Angle Runner No. 1 with clips is used at
right angles to the units (maximum distance to the first modular carrier 1600 mm)
and Angle Runner No. 2 is used parallel to
the units.
The narrow flange of the leading edge
return unit is supported by panhead self
tapping screws fixed into the angle runners
at max. 1600 mm centres.
The angle runners are fastened to the wall
at 500 mm intervals maximum.
To prevent movement of the ceiling,
modular carriers are braced against the
wall with timber battens as shown.
The first and the last modular carrier
should be braced at right angles approx.
every 2000 mm.
Align all the carrier clips accurately.
The wide flange of the first ceiling unit
should not be visible. Order a leading
edge return unit from DAMPA.