Combined-languages-d1 - Flipbook - Page 29
USER'S MANUAL
EVOLUTION VETERINARY DENTAL UNITS
29 � EN
BUR REPLACEMENT - iPUSH TOOL
Bur Replacement - iPush Tool (iM3 ordering code L7050)
1
2
1. Place the yellow iPush onto the LED Advantage
handpiece.
2. Depress the lever with your thumb and insert the bur
all the way until it stops.
3. Remove the iPush before using the Handpiece.
4. To change the Bur repeat step 2. and remove the Bur.
To increase the life of the Handpiece, Oil between
each use and replace the Bur between each patient,
(see Handpiece manual).
Fig.28 - Bur Replacement diagram
Handpieces included with your dental unit
will depend on the model purchased. Visit
www.im3vet.com to see which handpieces are
included with your unit.
iM3 ADVANTAGE LOW SPEED HANDPIECE
The low speed handpiece features include a light weight
balanced profile and smooth swivel action. Its vane type
power system is quiet and vibration free. The motor
accommodates both Doriot or ISO heads and its powerful
torque is suitable for all low speed procedures. The Low
speed Motor operates at 20,000 rpm with delivery pressure
of 40 psi.
Operation Recommendations
AIR PRESSURE The dental unit air pressure should be
adjusted to be 40 psi
Fig.29 - Low Speed Handpiece
iM3 Low Speed Handpieces Attachment
(1) 4:1 Advantage Straight Nose Cone (SNC) Attachment
L6250
The reducing head is designed for polishing (prophy).
The speed of the polishing cup should be maintained at
less than 5,000 rpm. The reducing attachment allows the
motor speed and torque to be maintained while reducing
the polishing speed. iM3 disposable oscillating prophy
angles are fitted to the SNC. They won’t trap muzzle hair, or
generate excessive heat. (iM3 R&R prophy cup Code L7466)
LUBRICATION To assure optimal performance and life,
the handpiece should be lubricated daily
with MD-30 oil lubricant.
AIR SUPPLY
Moist or dirty air from the compressor can
cause damage. Check the regulator filter
regularly. If dirt or moisture is present,
replace the regulator filter and bleed the
system, to remove water
Installation Instructions
1.
Connect the low speed handpiece to the grey
handpiece line
2.
Fit the 4:1 Advantage straight nose cone. Attach the Blue
R&R oscillating prophy head by simply pushing it on
3.
Depress the foot control fully to operate the low speed
handpiece
Polishing should be carried out at 5,000 rpm or
less. This can be accomplished by running the
motor at full revs (20,000 Rpm) and use a 4:1
reduction head (L6250), to achieve 5,000 revs,
maintaining torque.
Fig.30 - Advantage Straight Nose Cone attachment