DISPENSE SYSTEMS
GLYCOL COOLED
REMOTE
BEER SYSTEM
GAS BLEND LINE #2
70% CO2 & 30% N used
for lagers and ales.
The Power Pack is used to refrigerate a mix of water and glycol which is re-circulated at
a temperature between 29 – 32 F. This maintains a brewery recommended keg storage
temperature of 38 F. Glycol-cooled systems are not designed to lower beer dispensing
temperatures. The system is designed to deliver beer at the same temperature as the
walk-in-cooler.
Glycol-cooled systems are installed for long runs with a maximum length of 750 feet.
Connecting multiple beer dispensing stations in a single system makes a glycol-cooled
system highly functional and cost efficient.
SECONDARY
REGULATOR PANEL
Regulates gas pressure to
each products specification.
IN-PLACE CLEANING SYSTEM
Save beer and increase profits
by cleaning your own lines when
a keg empties.
EVAPORATOR UNIT
Creates refrigerated air
for walk-in cooler.
GAS BLEND LINE #1
25% CO2 and 75% N
used for stouts.
COUPLER
Dispense head for
tapping kegs.
TAIL LINE
Exposed product lines in
walk-in not touching
glycol lines.
MICRO MATIC
PRO-LINE™ BLENDER
KEG STACKER
Saves space while allowing two
kegs in series to be tapped.
HIGH PRESSURE
BRAIDED LINE
GLYCOL
COOLANT LINES
Transfer source for
glycol (Must be fully
wrapped inside cooler).
BEER HOSE
Transfer source
for beer.
KEGS
Contains beer
under pressure.
WALK-IN COOLER
N CYLINDER
Storage for N.
CO2 CYLINDER
Storage for CO2.
HIGH PRESSURE
REGULATORS
Regulates the CO2 and
N for the gas blend.
PROFIT MAXIMIZER™
(PRO-MAX)
Detects empty keg, closing
beer line and keeping it filled.
Eliminates wasted beer and
lost profits.
50 LITRE CLEANING BOTTLE
One bottle contains cleaning
chemicals and one contains rinse
water for the "In-Place
Cleaning System".
| 118
POWER PACK
(70% water / 30% Polar-Flo glycol)
is refrigerated to maintain product
temperature from walk-in cooler to tower.
Capable of up to 750 ft.