Micronic Product Catalog 2023 - Online version - Flipbook - Page 10
OVERVIEW AND SPECIFICATIONS
I N N O V A T I O N
IN
SAMPLE
STORAGE
TUBES WITH EXTERNAL THREAD HYBRID
0.75 ML
Ultra low temperature rack
Optional (DM = 2D Data-Matrix code on
rack bottom)
Thread type
Tube type
Inner tube shape
Working volume with Push Cap (+21ºC)*
Working volume with Screw Cap (+21ºC)*
Working volume with Screw Cap (-20ºC)*
Working volume with Screw Cap (-80ºC)*
2D Data-Matrix coded (bottom)
Alphanumeric coded (bottom)
Non-coded (bottom)
Human readable coded (bottom)
1D barcoded (side)
Human readable coded (side)
Capping options
Outer diameter
Tube height
Tube height with Push Cap
Tube height with Screw Cap IG
Tube height with Screw Cap
Available precapped
Twist-lock
Snap tube option
Sterilization option
DNase / RNase free
Class 7 clean room production
Minimum storage temperature***
Availability
1.40 ML
2.00 ML
3.00 ML
Page
30
Page
31
Page
32
Page
33
Micronic 96-2
DM
Micronic 96-4
DM
Micronic 48-2
External
Hybrid tube
V
External
Hybrid tube
V
0.57ml
0.62ml
0.62ml
0.60ml
1.50 ML
3.00 ML
6.00 ML
Page
34
Page
35
Page
36
Micronic 48-3
Micronic 24-1
Micronic 24-1
Micronic 24-4
External
Hybrid tube
Flat
External
Hybrid tube
Flat
External
Hybrid tube
Flat
External
Hybrid tube
Flat
External
Hybrid tube
Flat
1.03ml
1.20ml
1.06ml
0.95ml
n/a
1.95ml
1.80ml
1.65ml
n/a
2.90ml
2.60ml
2.60ml
n/a
1.45ml
1.40ml
1.30ml
n/a
2.45ml
2.25ml
2.25ml
n/a
6.00ml
5.55ml
5.30ml
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
No
No
Yes
Yes
No
No
No
No
Yes
Yes
No
No
No
Yes
Yes
Screw Cap (IG)
Push Cap
Screw Cap (IG)
Push Cap
Screw Cap
Screw Cap
Screw Cap
Screw Cap
Screw Cap
8.8mm
30.0mm
31.4mm
32.3mm
33.5mm
8.8mm
48.0mm
49.4mm
50.3mm
51.5mm
13.0mm
30.0mm
n/a
n/a
33.5mm
13.0mm
41.0mm
n/a
n/a
44.5mm
16.3mm
16.0mm
n/a
n/a
19.5mm
16.3mm
23.0mm
n/a
n/a
26.5mm
16.3mm
48.0mm
n/a
n/a
51.5mm
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Vapor phase LN2 Vapor phase LN2 Vapor phase LN2 Vapor phase LN2 Vapor phase LN2 Vapor phase LN2 Vapor phase LN2
Bulk, Rack
Bulk, Rack
Bulk, Rack
Bulk, Rack
Bulk, Rack
Bulk, Rack
Bulk, Rack
* If more sample volume is used in a tube than the specified working volume, it could be possible that deformation of the tube occurs. Request Test Report TR023201 for more information.
** Temperature range of the material of the tubes, caps and racks is approved from -80ºC to +100ºC. In practice tubes are used in lower temperatures until vapor phase LN2
(-150ºC to -196ºC). Micronic does not recommend to store tubes in liquid phase nitrogen (LN2). In practice tubes are only snap freezed in LN2 (without submerging the cap).
10
MICRONIC | Innovation in sample storage